A solar power plant covers a lot of ground and contains a very large number of modules. Metering data tells you output has dropped, but it does not tell you which array, which string, or which module is responsible. Walking the rows on foot is slow, and many of the faults that matter are invisible to the naked eye. Drone inspection exists to close that gap.
What the inspection actually detects
Solar inspection normally combines two data types: thermal imagery, which reveals temperature differences caused by electrical faults, and visible-light imagery, which confirms what is physically at that location. The usual findings include:
- Hotspots — localised heating on part of a cell, often a sign of damage or an internal defect.
- String-level anomalies — a whole series-connected run showing a different thermal signature, pointing to wiring or combiner box issues.
- Bypass diode symptoms — a distinct temperature pattern affecting only one section of a module.
- Soiling and shading — bird droppings, dust accumulation, and shadows cast by vegetation or nearby structures.
- Physical damage — cracked glass, deformed frames, backsheet defects, all visible in standard imagery.
- Site and structure condition — tilted mounting frames, foundation settlement, blocked drainage, encroaching vegetation.
Capture conditions are half the result
Thermal inspection is highly sensitive to when you fly. Modules need to be under real electrical load from sufficient sunlight before a faulty module will read differently from a healthy one. Fly on an overcast day or early in the morning and genuine defects can simply fail to appear in the imagery.
The capture itself has requirements too. The camera should point close to perpendicular to the module surface to reduce reflection artefacts, and altitude should be set so that the ground area covered by each pixel is small enough to resolve the defects you care about. Sufficient image overlap is what allows the whole site to be stitched into a single map afterwards. Strong wind causes airframe movement that smears thermal imagery, so rescheduling is usually better than flying through it. Exact altitudes and capture intervals depend on sensor specification and site layout, so they should be designed per site rather than copied from a template.
From raw data to an action list
The deliverable of a drone inspection should be an actionable list, not a folder of photographs. In practice, captured imagery is aligned into a site-wide map, then matched against the plant layout so every anomaly can be tagged with an array and string reference. That is what lets a maintenance technician walk straight to the right location.
Findings are then graded by the size and shape of the temperature difference and sorted into priorities: fix now, verify at the next scheduled inspection, or monitor. Once several inspection cycles have accumulated, patterns emerge — the same location recurring, or defects clustering in one construction zone. It is worth being clear about the limits, though: drone inspection narrows down candidate faults, it does not deliver a final diagnosis. Confirmed locations still need on-site electrical measurement to establish the cause.
Regulatory groundwork before you fly in Korea
Inspection performed for a fee is commercial flight, and that changes what is required.
- Aircraft registration: for commercial purposes, every airframe must be registered regardless of weight. This is easy to confuse with the non-commercial rule, where registration applies above 2kg maximum take-off weight.
- Insurance: under Article 70 of the Aviation Business Act, ultralight vehicle commercial operators must hold insurance or mutual aid cover. The statutory minimum is 150 million KRW per person for bodily injury and 20 million KRW per incident for property damage. Flying without it carries an administrative fine of up to 5 million KRW.
- Sequence: insurance first, then aircraft registration, then business registration. Companies frequently start at the wrong end and have to backtrack.
- Flight approval: required above 150m altitude and inside controlled airspace or no-fly zones. Violations draw an administrative fine of up to 3 million KRW, while unauthorised flight in restricted airspace is a criminal fine of up to 5 million KRW.
Solar sites are often located near airports or military facilities, so checking the site coordinates should come first, not last. Applications are handled through the Drone One-Stop civil service portal. Note that aerial filming permission is administered separately by the Ministry of National Defense and is not covered by a flight approval — both need to be confirmed. If night or beyond-visual-line-of-sight operations are ever contemplated, a special flight approval is required, and review takes 30 days as standard, extending to 90 days in exceptional cases. Build that lead time into the project schedule rather than discovering it late.
Light Beyond Drones is based in Daejeon and runs industrial drone data services alongside a pilot training academy. Tell us the location and scale of the site and what you want to detect, and we will start by working out what data you actually need and how often. If you intend to run inspections with in-house staff rather than outsourcing, the required pilot certification and safety management practices can be built up through our academy programme.